XQP500
500 kVA Mobile Diesel Generator Set
More Comfort – More Performance – More Versatility
-
Selectable 50/60Hz Operation
Easy frequency switch via terminal link eliminate geographical limitations allowing generator set to be used wherever it is needed
-
Flexible 3-way fuel valve
Extended run time provided by changeover from base tank to external bulk tank
-
Standard 500 Hour oil change intervals
Maximizes run time before routine service is required
Generator Set
| Frequency | 50/60 Hz |
| Rating Prime | 500 kVA |
| Voltage | 127 - 480 V |
Engine
| Engine | Cat C15 |
| Fuel | Diesel |
Dimensions
| Height | 90 in |
| Length | 200.9 in |
| Weight - With Lube Oil and Coolant | 13176 lb |
| Width | 77 in |
Fuel Consumption EU Stage IIIA
| 100% Load 50Hz | 29.1 gal/hr |
| 100% Load 60Hz | 32 gal/hr |
| 50% Load 50Hz | 16.4 gal/hr |
| 50% Load 60Hz | 18.3 gal/hr |
| 75% Load 50Hz | 23 gal/hr |
| 75% Load 60Hz | 26.3 gal/hr |
Fuel consumption Best Fuel Efficiency
| 100% Load 50Hz | 29 gal/hr |
| 100% Load 60Hz | 28.3 gal/hr |
| 50% Load 50Hz | 14.3 gal/hr |
| 50% Load 60Hz | 15.7 gal/hr |
| 75% Load 50Hz | 20.1 gal/hr |
| 75% Load 60Hz | 22 gal/hr |
Noise rating (with enclosure) EU Stage IIIA
| Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz) | 77.5 dB(A) |
| Sound Power @ 1 meters (3 feet) @ 75% of rating (60Hz) | 79.8 dB(A) |
Noise rating (with enclosure) Best Fuel Efficiency
| Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz) | 80.1 dB(A) |
| Sound Power @ 1 meters (3 feet) @ 75% of rating (60Hz) | 80 dB(A) |
Get info about our financing options
Get The best solution for your job site needs
Let us help.
Generator Set
| Frequency | 50/60 Hz |
| Rating Prime | 500 kVA |
| Voltage | 127 - 480 V |
Engine
| Engine | Cat C15 |
| Fuel | Diesel |
Dimensions
| Height | 90 in |
| Length | 200.9 in |
| Weight - With Lube Oil and Coolant | 13176 lb |
| Width | 77 in |
Fuel Consumption EU Stage IIIA
| 100% Load 50Hz | 29.1 gal/hr |
| 100% Load 60Hz | 32 gal/hr |
| 50% Load 50Hz | 16.4 gal/hr |
| 50% Load 60Hz | 18.3 gal/hr |
| 75% Load 50Hz | 23 gal/hr |
| 75% Load 60Hz | 26.3 gal/hr |
Fuel consumption Best Fuel Efficiency
| 100% Load 50Hz | 29 gal/hr |
| 100% Load 60Hz | 28.3 gal/hr |
| 50% Load 50Hz | 14.3 gal/hr |
| 50% Load 60Hz | 15.7 gal/hr |
| 75% Load 50Hz | 20.1 gal/hr |
| 75% Load 60Hz | 22 gal/hr |
Noise rating (with enclosure) EU Stage IIIA
| Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz) | 77.5 dB(A) |
| Sound Power @ 1 meters (3 feet) @ 75% of rating (60Hz) | 79.8 dB(A) |
Noise rating (with enclosure) Best Fuel Efficiency
| Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz) | 80.1 dB(A) |
| Sound Power @ 1 meters (3 feet) @ 75% of rating (60Hz) | 80 dB(A) |