C7.1 ACERT
135 - 220 kVA Diesel Generator Set
More Comfort – More Performance – More Versatility
-
Suitable for Harsh & Testing environments
-
Optimised for 5% Lower Fuel Consumption
Longer run times between fuel fills; reduced operating costs
-
Reliability tested for over 500 Hours
Ensures you can count on emergency power when it is needed
Generator Set Specifications
Duty Cycle | Standby, Prime |
Emissions/Fuel Strategy | Non Regulated, EU Stage IIIA |
Frequency | 50 Hz |
Maximum Rating | 220 kVA |
Minimum Rating | 135 kVA |
Speed | 1500 rpm |
Voltage | 110 to 480 Volts |
Engine Specifications
Aspiration | Turbocharged, Air to Air Aftercooled |
Bore | 4.1 in |
Compression Ratio | 16.0:1, 18.2:1 |
Displacement | 427.8 inÂł |
Engine Model | Cat® C7.1 |
Fuel System | Direct Injection |
Governor Type | Mechanical |
Stroke | 5.3 in |
Generator Set Dimensions
Height - Maximum | 64 in |
Length - Maximum | 98.4 in |
Width - Maximum | 52 in |
Download resources
Electric Power Ratings Guide
DE150E0 50 Hz 150.0 kVA, 60 Hz, 165.0 ekW, LC-Frame, Low BSFC Compliant Spec Sheet
DE165E0 50 Hz 165.0 kVA, 60 Hz, 187.5 ekW, LC-Frame, Low BSFC Compliant Spec Sheet
DE165E3 50 Hz 165.0 kVA, LC-Frame, EU IIIA Compliant Spec Sheet
DE175E3 50 Hz 175.0 kVA, LC-Frame, EU IIIA Compliant Spec Sheet
DE200E0 50 Hz 200.0 kVA, 60 Hz, 218.8 ekW, LC-Frame, Low BSFC Compliant Spec Sheet
DE200E3 50 Hz 200.0 kVA, LC-Frame, EU IIIA Compliant Spec Sheet
DE220E0 50 Hz 220.0 kVA, LC-Frame, Low BSFC Compliant Spec Sheet
DE150E0 50 Hz 150.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
DE165E0 50 Hz 165.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
DE165E3 50 Hz 165.0 kVA, M-Frame, EU IIIA Compliant Spec Sheet
DE200E0 50 Hz 200.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
DE200E0 50 Hz 200.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
DE200E3 50 Hz 200.0 kVA, M-Frame, EU IIIA Compliant Spec Sheet
DE220E0 50 Hz 200.0 kVA, M-Frame, Low BSFC Compliant Spec Sheet
DE165E0 50 Hz 165.0 kVA, 60 Hz 187.5 kVA, R-Frame, Low BSFC Compliant Spec Sheet
DE165E0 50 Hz 165.0 kVA, 60 Hz 187.5 kVA, R-Frame, Low BSFC Compliant Spec Sheet
DE200E0 50 Hz 200.0 kVA, 60 Hz 218.8 kVA, R-Frame, Low BSFC Compliant Spec Sheet
DE165E3 50 Hz 165.0 kVA, R-Frame, EU IIIA Compliant Spec Sheet
DE220E0 50 Hz 220.0 kVA, R-Frame, Low BSFC Compliant Spec Sheet
Get info about our financing options
Get The best solution for your job site needs
Let us help.
Generator Set Specifications
Duty Cycle | Standby, Prime |
Emissions/Fuel Strategy | Non Regulated, EU Stage IIIA |
Frequency | 50 Hz |
Maximum Rating | 220 kVA |
Minimum Rating | 135 kVA |
Speed | 1500 rpm |
Voltage | 110 to 480 Volts |
Engine Specifications
Aspiration | Turbocharged, Air to Air Aftercooled |
Bore | 4.1 in |
Compression Ratio | 16.0:1, 18.2:1 |
Displacement | 427.8 inÂł |
Engine Model | Cat® C7.1 |
Fuel System | Direct Injection |
Governor Type | Mechanical |
Stroke | 5.3 in |
Generator Set Dimensions
Height - Maximum | 64 in |
Length - Maximum | 98.4 in |
Width - Maximum | 52 in |