fbpx
Skip to content
C175-20

C175-20

3150 - 4000 ekW Diesel Generator Set

More Comfort – More Performance – More Versatility

  • Over 20,000,000 Operating hours

    at Global locations

  • Over 3000 units

    In the field

  • Highest Rated Tier 4 Product

    Available on the market

Generator Set Specifications

Duty Cycle Standby, Mission Critical, Prime, Continuous
Emissions/Fuel Strategy Low Fuel, Tier 2
Frequency 60 Hz
Maximum Rating 4000 ekW
Minimum Rating 3150 ekW
Prime Power Rating 3600 (no fan)/3500/3300 (no fan)/3180 ekW
Speed 1800 rpm
Standby Rating 4000 (no fan)/3900/3620(no fan)/3500 ekW
Voltage 480 to 13800 Volts

Engine Specifications

Aspiration Turbo Aftercooled
Bore 6.89 in
Compression Ratio 15.3:1
Displacement 6456.31 in³
Engine Model C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel
Fuel System Common Rail
Governor Type ADEM� A4
Stroke 8.66 in

Generator Set Dimensions

Dry Weight - Genset (maximum) 66200 lb
Dry Weight - Genset (minimum) 55100 lb
Height - Maximum 150.7 in
Height - Minimum 87.6 in
Length - Maximum 330.6 in
Length - Minimum 261.5 in
Width - Maximum 127.7 in
Width - Minimum 85.4 in

Download resources

Electric Power Rating Guide
C175-20, 60 Hz, 3500 ekW Standby/MC, 3180 ekW Prime U.S. EPA Stationary Emergency (Tier 2) (with fan) Spec Sheet
C175-20, 60 Hz, 3900 ekW Standby/MC, 3500 ekW Prime, 3150 ekW Cont., Low Fuel Consumption (with fan) Spec Sheet
C175-20, 60 Hz, 3900 ekW Standby/MC, 3500 ekW Prime, 3150 ekW Cont. U.S. EPA Stationary Emergency (Tier 2) (with fan) Spec Sheet
C175-20, 60 Hz, 4000 ekW Standby/MC, 3600 ekW Prime, 3250 ekW Cont., Low Fuel Consumption (without fan) Spec Sheet
C175-20, 60 Hz, 3620 ekW Standby/MC, 3300 ekW Prime U.S. EPA Stationary Emergency (Tier 2) (without fan) Spec Sheet
C175-20 60 Hz 4000 ekW Standby/MC, 3600 ekW Prime, 3250 ekW Cont., US. EPA Stationary Emergency (Tier 2) (without fan) Spec Sheet
C175-20, 60 Hz, 3180 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (with fan) Spec Sheet
C175-20, 60 Hz, 3300 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (without fan) Spec Sheet
C175-20, 60 hz, 3500 ekW Prime-DCP, Low Fuel Consumption (with fan) Spec Sheet
C175-20, 60 Hz, 3500 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (with fan) Spec Sheet
C175-20, 60 Hz, 3600 ekW, Prime-DCP, Low Fuel Consumption (without fan) Spec Sheet
C175-20, 60 Hz, 3600 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (without fan) Spec Sheet

Get info about our financing options

Get The best solution for your job site needs

Let us help.

Name(Required)
Untitled

Call us today: 1-877-778-2230
or  Send us a message