Skip to content
C175-16 Generator Set

C175-16 Generator Set

2500 - 3365 ekW Diesel Generator Set

More Comfort – More Performance – More Versatility

  • Over 20,000,000 Operating hours

    at Global locations

  • Over 3000 units

    In the field

  • Highest Rated Tier 4 Product

    Available on the market

Generator Set Specifications

Duty Cycle Standby, Mission Critical, Prime, Continuous
Emissions/Fuel Strategy Low Fuel, Tier 2
Frequency 60 Hz
Maximum Rating 3365 ekW
Minimum Rating 2500 ekW
Prime Power Rating 3115(no fan)/3000/2825(no fan)/2725 ekW
Speed 1800 RPM
Standby Rating 3365(no fan)/3250/3100(no fan)/3000 ekW
Voltage 480 to 13800 Volts

Engine Specifications

Aspiration Turbo Aftercooled
Bore 6.89 in
Compression Ratio 16.7:1
Displacement 6456.31 in³
Engine Model C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Fuel System Common Rail
Governor Type ADEM� A4
Stroke 8.66 in

Generator Set Dimensions

Dry Weight - Genset (maximum) 50500 lb
Dry Weight - Genset (minimum) 42750 lb
Height - Maximum 134.3 in
Height - Minimum 87 in
Length - Maximum 312.9 in
Length - Minimum 241.6 in
Width - Maximum 113.7 in
Width - Minimum 83.1 in

Download resources

Electric Power Rating Guide
C175-16, 60 Hz, 3000 ekW Standby/MC.2725 ekW Prime, 2500 ekW Cont., Low Fuel Consumption (with fan) Spec Sheet
C175-16, 60 Hz, 3000 ekW Standby/MC.2725 ekW Prime, 2500 ekW Cont., U.S. EPA Stationary Emergency (Tier 2) (with fan) Spec Sheet
C175-16, 60 Hz, 3100 ekW Standby/MC, 2825 ekW Prime, 2600 ekW Cont., Low Fuel Consumption (without fan) Spec Sheet
C175-16, 60 Hz, 3100 ekW Standby/MC, 2825 ekW Prime, 2600 ekW Cont., U.S. EPA Stationary Emergency (Tier 2) (without fan) Spec Sheet
C175-16, 60 Hz, 3250 ekW Standby/MC, 3000 ekW Prime, U.S. EPA Stationary Emergency (Tier 2) (with fan) Spec Sheet
C175-16, 60 Hz, 3365 ekW Standby/MC, 3115 ekW Prime, U.S. EPA Stationary Emergency (Tier 2) (without fan) Spec Sheet
C175-16, 60 Hz, 2725 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (with fan) Spec Sheet
C175-16, 60 Hz, 2725 ekW, Prime-DCP, Low Fuel Consumption (with fan) Spec Sheet
C175-16, 60 Hz, 2825 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (without fan) Spec Sheet
C175-16, 60 Hz, 2825 kVA, Prime-DCP, Low Fuel Consumption (without fan) Spec Sheet
C175-16, 60 Hz, 3000 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (with fan) Spec Sheet
C175-16, 60 Hz, 3115 ekW, Prime-DCP, U.S. EPA Stationary Emergency Use Only (Tier 2) (without fan) Spec Sheet

Get info about our financing options

Get The best solution for your job site needs

Let us help.